301, Building 2, Houhai Industrial Park, Liyuhe Industrial Zone, Loucun Community, Xinhu Street, Guangming District, Shenzhen
Product : High Frequency Transformer-less Double-conversion Online UPS Model : JHF-11 (1kVA-10kVA) Input Voltage : 1 x 220VAC (1Phase + N) (Can Customized) Input Range : 110-300 VAC (Based on load at 50%) Output Voltage :1 x 220VAC (1Phase + N) (Can Customized) Output Accuracy : ±1% Phase : Single Phase
JHF-11 series 1kVA to 10kVA (L) is a full DSP controlled, Adopt 3-level-Inverter technology,
online double conversion,1/1 Phase pure sine wave UPS, with multi-functional
and high available design, system overall efficiency above 95%,JHF-11 series
can be defined as a high reliability and energy saving green power.
◆ JHF Series is a full DSP controlled, adopting latest 3-Level-Inverter technology to meet the critical loads.
◆ Online double conversion,1/1 Phase pure sine wave online UPS.
◆ With smart design and high reliable, this system overall efficiency.
◆ Output PF=1.0,overall efficiency above 95%
◆ Can be connected with all kinds of generators to save customers costs.
◆ Energy saving green power.
◆ Intelligent battery management, UPS charging current can be adjustable from 1-12A;
◆ Powerful overload ability with output short circuit protection technology which can high make sure the UPS reliability and system safety under critical status.;
◆ Large Color Dot-matrix LCD+LED Screen with multi function and user- friendly.
◆ Compact size, smart design, high reliability.
Model |
JHF-1101(L) |
JHF-1102(L) |
JHF-1103(L) |
JHF-1106(L) |
JHF-1110(L) |
|
|
JHF-1101(L)-RM |
JHF-1102(L)-RM |
JHF-1103(L)-RM |
JHF-1106(L)-RM |
JHF-1110(L)-RM |
|
Capacity |
1KVA/1KW |
2KVA/2KW |
3KVA/3KW |
6KVA/6KW |
10KVA/10KW |
|
Host Machine Specification |
||||||
UPS Structure |
Online Double Conversion |
|||||
Appearance |
Tower or Rack mount structure design |
|||||
Overall Efficiency |
> 95%(98.5% under ECO mode) |
|||||
Noise(In 2 meters) |
< 50dB |
|||||
Working Temp |
-10-40℃ |
|||||
Storage Temp |
-15-60℃(without batteries) |
|||||
Humidity |
< 20-95% Non-Condensing |
|||||
Safety Standard |
GB/T 7260, GB/T 4943, YD/T1095, TLC |
|||||
Safety Standard |
EN/IEC 61000, EN/IEC 62040, |
|||||
Maintenance bypass |
/ |
optional |
||||
protection |
Overload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low |
|||||
Alarm |
Mains abnormal or Fault, BAT Voltage High/low,over load、UPS fault, shot circuit etc |
|||||
ECO mode |
available |
|||||
EPO mode |
available |
|||||
DC start |
available |
|||||
Generator compatibility |
available |
|||||
Display |
LCD Display: Multi-Language with all kinds of messages. Input/ Output /bypass Status, ECO Mode , charging status, load status, Rectifier status, INV. Temp, LED Indicators: UPS States Indicator |
LCD Display: Multi-Language with all kinds of messages. Input/ Output /bypass Status, ECO Mode , charging status, load status, Rectifier status, INV. Temp,
Colored LCD screen:Working (days);SN;Calendar、time;UPS model & structure;Version No.;history log records;history fault records;language set;ECO set; time & calendar set;battery test & so on. LED Indicators: UPS States Indicator |
||||
Mute |
Automatic |
|||||
Cabinet Standard |
IP20 |
|||||
Cooling System |
Intelligent Speed Control Cooling Fan |
|||||
Altitude |
<11000M,Without Derated, 1000m <altitude< 1500m, refer to IEC62040 |
|||||
Rectifier Specification |
||||||
Input Voltage |
220Vac(208/220/230/240Vac available) |
|||||
Input Voltage Range |
100%load:180-300Vac,50% load:110-300Vac |
110~300Vac 110~176VAC/276~300VAC |
||||
Input Frequency Range |
44~56Hz or 54Hz~66Hz |
|||||
Input PF |
0.99 |
|||||
THDI |
≤ 3% linear load,≤ 5% Non-linear load |
|||||
Output Specification |
||||||
Output Voltage |
220Vac(208/220/230/240Vac available) |
|||||
Output PF |
1.0 (0.9 default type) |
|||||
Output Voltage Regulation |
220Vac±1%(Static Load);220Vac±2%(50-0% Sudden Change);220Vac±5%(100-0% Sudden Change) |
|||||
Output Freq(utility) |
46Hz≤input Freq.≤54Hz,output Freq.=input Freq.; When Input Freq.<46Hz or >54Hz, Locked at 50Hz |
|||||
Output Freq(Battery) |
50Hz±0.1%(Battery mode) |
|||||
Wave form |
Pure sine wave |
|||||
Distortion |
< 2%(Linear Full Load),< 4%(100% Non-Linear Full Load) |
|||||
Overload |
125% More than 1 Min; >150% bypass mode and UPS turn off |
◆Utility mode: 125%~150% load, more than 30s ◆Battery mode: |
||||
Crest Ratio |
3∶1 |
|||||
Inverter efficiency |
> 95% |
|||||
Short circuit |
Circuit Auto Protection,Output Voltage/Current 0 |
|||||
Output Abnormal |
INV. Output Auto-Locked Protection |
|||||
Noise Suppression |
EMI/RFI Wave Filter |
|||||
Battery voltage low |
Shut down protection |
|||||
Dynamic Response |
3% at full load, recovering in 20ms |
|||||
Auto restart function |
available |
|||||
Software set on/off |
available |
|||||
Bypass Specification |
||||||
Static Bypass Transfer Time |
0ms(the Static breaker phase lock control technology) |
|||||
Static Bypass Range |
80Vac±5%~285Vac±5% |
|||||
Bypass -> INV Transfer Time |
< 2ms |
|||||
Battery Specification |
||||||
Type |
Sealed Lead Acid Maintenance Free |
|||||
Model Rated Volts/Units |
12V/7Ah*2nos |
12V/7Ah*4nos |
12V/7Ah*6nos |
12V/7Ah*16nos |
||
Std. Built-in BAT type backup time |
5-15mim |
5-15mim |
5-15mim |
5-15mim |
5-15mim |
|
Ext. Model rated voltage |
36Vdc |
72Vdc |
96Vdc |
192 Vdc defult /240Vdc (optional) |
||
Charging current |
Std.Built-in model 1A、Ext. model 5-10A |
Std. Built-in model 1A、Ext. model 6-12A |
||||
Communication Specification |
||||||
Communication Port |
Std.RS232/EPO;SNMP/485/dry contact(optional) |
|||||
Remote Software |
Multi-functional Monitoring System, Online and BAT Mode Status, utility fault, BAT Fault, Remote Control |
|||||
Physical Parameters |
||||||
Size mm (W×D×H) |
Std. type |
145×285×215 |
145×400×215 |
190×420×318 145×400×215 |
190×390×705 |
|
Ext. type |
190×360×335 |
|||||
RM/RT type |
440×400×88/2U |
440×450×88/2U |
||||
Weight Kg |
9/5 |
15/7 |
20/8 |
57/12 |
67.5/12.5 |
|
5 |
7 |
8 |
12 |
12.5 |
Note:In the model name “L”represent“ long run battery external type. Specification are subject to change without further notice.
No |
Model |
Power Rating |
DC Votlage |
Product Size (mm) |
Net Weight (KG) |
Single Phase Input and Single Phase Output (Tower Type) |
|||||
1 |
JHF-1101 |
1KVA/1KW |
24VDC |
292*145*224 |
3.8 |
2 |
JHF-1101L |
1KVA/1KW |
36VDC |
7.8 |
|
3 |
JHF-1102 |
2KVA/2KW |
48VDC |
400*145*224 |
13.5 |
4 |
JHF-1102L |
2KVA/2KW |
72VDC |
5.5 |
|
5 |
JHF-1103 |
3KVA/3KW |
72VDC |
384*190*318 |
19 |
6 |
JHF-1103L |
3KVA/3KW |
96VDC |
400*145*224 |
5.7 |
7 |
JHF-1106 |
6KVA/6KW |
192VDC |
384*190*700 |
51.2 |
8 |
JHF-1106L |
6KVA/6KW |
192VDC |
384*190*318 |
12 |
9 |
JHF-1110 |
10KVA/10KW |
192VDC |
384*190*700 |
51.2 |
10 |
JHF-1110L |
10KVA/10KW |
192VDC |
384*190*318 |
13 |
Single Phase Input and Single Phase Output (Rackmount Type) |
|||||
1 |
JHF-1101-RM |
1KVA/1KW |
24VDC |
400*440*88 |
11 |
2 |
JHF-1101L-RM |
1KVA/1KW |
36VDC |
7 |
|
3 |
JHF-1102-RM |
2KVA/2KW |
48VDC |
15.5 |
|
4 |
JHF-1102L-RM |
2KVA/2KW |
72VDC |
7.7 |
|
5 |
JHF-1103-RM |
3KVA/3KW |
72VDC |
540*440*88 |
20 |
6 |
JHF-1103L-RM |
3KVA/3KW |
96VDC |
400*440*88 |
8 |
7 |
JHF-1106L-RM |
6KVA/6KW |
192VDC |
450*440*88 |
10.5 |
8 |
JHF-1110L-RM |
10KVA/10KW |
192VDC |
11 |
|
1. The above Sizes and Weights are our standard type for your information. |
|||||
2. Customized products maybe with different sizes and weights. |
|||||
3. Product specifications are subject to change without further notice. |
This product is widely used for Bank/Securities clearing center, Cash register, ATM, Automatic shutter door, PC terminal user, Communication equipment such as fax machine, telephone and SPC Switch, Office automation system, Commercial infrastructure,mechanical processing equipment, transportation, scientific research, industry, transportation, railways, elevators, medical equipment, air-conditioning, radio and television, household appliances, lighting, new energy and other power-consuming occasions that need to be stabilized.