301, Building 2, Houhai Industrial Park, Liyuhe Industrial Zone, Loucun Community, Xinhu Street, Guangming District, Shenzhen
Product : High Frequency Transformer-less Double-conversion Online UPS Model : SHF-11 (1kVA-10kVA) Input Voltage : 1 x 220VAC (1Phase + N) (Can Customized) Input Range : 110-300 VAC (Based on load at 50%) Output Voltage :1 x 220VAC (1Phase + N) (Can Customized) Output Accuracy : ±1% Phase : Single Phase
SHF-11-LV series 1kVA to 6kVA (L) series low-voltage (110V/120V)UPS is a new generation of general purpose products of Shenzhen SST Power, which can be adapted to 100/110/120/127V electrical equipment, optional frequency adaptive and fixed frequency mode to ensure that the machine can adapt to various different environments, and this UPS can further cooperate with the isolation transformer output 380V/600V and other special voltages. Suitable for IT equipment, as well as industrial and mining field automatic control system.
•Zero switching time
•Load power factor up to 0.9
•Input power factor up to 0.99
•Three anti-paint process, special dustproof design
•85V-300V ultra-wide input voltage range
•Using DSP digital control technology
•Multiple output voltages are available.
•Perfect compatibility with various loads
•Realize online double conversion
•Microprocessor control ensures high reliability
•Input power factor correction
•Output power factor up to 0.8
•Wide mains input range (110 V - 300 V)
•Efficient conversion mode
•Compatible generator
•Optional exquisite SNMP card can be alone or with USB, RS232 together to monitor perfectly
•Through the display, simple operation control, and comprehensive shows the status of monitoring UPS
High Frequency Single Phase Online UPS | |||||||
Items |
RHF-1101K (L) | RHF-1102K (L) | RHF-1103K (L) | RHF-1106K (L) | RHF-1110K (L) | ||
Phase |
Single Phase | ||||||
Power Rating |
1000 VA / 800 W | 2000 VA / 1600 W | 3000 VA / 2400 W | 6000 VA / 4800 W | 10000 VA / 8000 W | ||
Input | |||||||
Input Voltage Range/Window |
55-150 VAC or 110-300 VAC at 50% load 85-140 VAC or 160-280 VAC at 100% load |
110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%) |
|||||
Frequency |
40Hz ~ 70 Hz |
46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
|||||
Power Factor |
100% load≧0.99 |
||||||
Output | |||||||
Output Voltage |
200/208/220/230/240VAC |
208/220/230/240VAC |
|||||
Voltage Range (Battery Mode) |
± 1% |
||||||
Frequency(Synchronization correction range) |
47~ 53 Hz or 57 ~ 63 Hz |
46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
|||||
Frequency (Battery Mode) |
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz |
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
|||||
Surge Ratio |
3:1 |
||||||
Harmonic Distortion |
≦ 3% THD (Linear Load) ≦6% THD (Nonlinear Load) |
≦ 3% THD (Linear Load) ≦5% THD (Nonlinear Load) |
|||||
Transfer Time |
AC to DC |
0ms |
|||||
Inversion to Bypass |
4 ms (Standard ) |
0ms |
|||||
Waveform(Battery Mode) |
Pure Sine Wave |
||||||
Efficiency | |||||||
Bypass Mode |
88% |
|
88% |
90% |
92% |
93% |
|
Battery Mode |
83% |
|
85% |
88% |
90% |
91% |
|
Battery |
Standard model | Battery Model | 12V / 9AH | ||||||
Quantity | 2 | 4 | 6 | 16 | 20 | 16 | 20 | |
The Max Charging Current | 1.0A(Max) | Preset:1.0 A ± 10%, Max.:2.0A ± 10% | ||||||
Charging Voltage | 27.4VDC ± 1% | 54.7VDC ± 1% | 82.1VDC ± 1% | 218.4 VDC ± 1% | 273 VDC ± 1% | 218.4 VDC ± 1% | 273 VDC ± 1% | |
Long Run model | Battery Model | It ups to the User's requirement | ||||||
Quantity | 2 | 3 | 4 | 6 | 6 | 8 | 16-20(Adjustable)** | |
The Max Charging Current | 1A/2A/4A/6A(Adjustable) | 1A/2A/4A/6A(Adjustable,6A(Only sutible for 16pcs batteries) | ||||||
Charging Voltage | 27.4VDC ± 1% | 41.0VDC ± 1% | 54.7VDC ± 1% | 82.1VDC ± 1% | 82.1VDC ± 1% | 109.4VDC ± 1% | 273VDC ± 1%(When 20pcs batteries) | |
Apperance | ||||||||
LCD or LED Display | Load size, Battery power, Mains Supply Mode, Battery mode,Failure instruction | |||||||
Alarm | ||||||||
Battery Mode | Sound every 4 seconds | |||||||
Low Battery | Sound every second | |||||||
Over-load | Sound every second | |||||||
Fault | Continuous sounding | |||||||
Physical Performance | ||||||||
Standard model | Size,WxDxH(mm) | 145 X282 X 220 | 145 X397 X 220 | 190 X421 X 318 | 190 x369x688 | 190 x369x688 | ||
Net Weight(KG) | 9.8 | 17 | 27.6 | 61 | 74 | 66 | 75 | |
Long Run Model | Size,WxDxH(mm) | 145 X282 X 220 | 145 X397 X 220 | 190 x369 x 318 | 190 x442 x 318 | |||
Net Weight(KG) | 4.1 | 6.8 | 7.4 | 12 | 16 | 18 | ||
Operating Environment | ||||||||
Temperature & Humidity | Relative humidity 20-90 % and temperature 0- 40°C (No condensation ) | Relative humidity 0-95 % and temperature 0- 40°C (No condensation ) | ||||||
Noise | less 50dBA @1 Meter | Less 55dBA @ 1 Meter | Less 58dB @ 1 Meter | |||||
Control Management | ||||||||
Smart RS-232 / USB | Support Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | |||||||
SNMP(Option) | Power management support SNMP management and network management |
No |
Model |
Power Rating |
DC Votlage |
Product Size (mm) |
Net Weight (KG) |
Single Phase Input and Single Phase Output (Tower Type,Standard Type) |
|||||
1 |
SHF-1101 |
1KVA/0.8KW |
24VDC |
145 X282 X 220 |
9.8 |
2 |
SHF-1102 |
2KVA/1.6KW |
48VDC |
145 X397 X 220 |
17 |
3 |
SHF-1103 |
3KVA/2.4KW |
72VDC |
190 X421 X 318 |
27.6 |
4 |
SHF-1106 |
6KVA/4.8KW |
192VDC |
190 x369x688 |
61 |
5 |
SHF-1110 |
10KVA/8KW |
192VDC |
190 x369x688 |
66 |
Single Phase Input and Single Phase Output (Tower Type, Long-run Type) |
|||||
1 |
SHF-1101L |
1KVA/0.8KW |
36VDC |
145 X282 X 220 |
4.1 |
2 |
SHF-1102L |
2KVA/1.6KW |
72VDC |
145 X397 X 220 |
6.8 |
3 |
SHF-1103L |
3KVA/2.4KW |
96VDC |
190 x369 x 318 |
7.4 |
4 |
SHF-1106L |
6KVA/4.8KW |
192VDC |
190 x369 x 318 |
12 |
5 |
SHF-1110L |
10KVA/8KW |
192VDC |
190 x442 x 318 |
16 |
1. The above Sizes and Weights are our standard type for your information. |
|||||
2. Customized products maybe with different sizes and weights. |
|||||
3. Product specifications are subject to change without further notice. |
This product is widely used for Bank/Securities clearing center, Cash register, ATM, Automatic shutter door, PC terminal user, Communication equipment such as fax machine, telephone and SPC Switch, Office automation system, Commercial infrastructure,mechanical processing equipment, transportation, scientific research, industry, transportation, railways, elevators, medical equipment, air-conditioning, radio and television, household appliances, lighting, new energy and other power-consuming occasions that need to be stabilized.