Product                               :All-in-one Off-Grid solarcharger inverter 
Power Rating                   :3000W~30kW
Input Voltage                   :1 x 220V/230VAC (1Phase + N)
Rated Output Voltage :230vac
Output Accuracy            :±5%
Phase                                    :Single Phase
Other voltages or requirements can be customized.
Tel:+8618718357506

 

Models

HF4830S60-145

HF4840S80 -145

HF4850S80-145

HF4825U80 -145

HF4830U80 -145

HF4835U80-145

AC mode

Rated input voltage

220/230Vac

110/120Vac

Input voltage range

(170Vac~280Vac) ±2%

(90Vac~140Vac) ±2%

 

 

 

Frequency

50Hz/ 60Hz (Auto detection)

Frequency Range

47±0.3Hz ~ 55±0.3Hz (50Hz);

 

57±0.3Hz ~ 65±0.3Hz (60Hz);

Overload/short circuit protection

Circuit breaker

Efficiency

>95%

Conversion time (bypass and inverter)

10ms (typical)

AC reverse protection

Available

Maximum bypass overload current

30A

40A

Inverter mode

Output voltage waveform

Pure sine wave

Rated output power (VA)

3000

4000

5000

2500

3000

3500

Rated output power (W)

3000

4000

5000

2500

3000

3500

Power factor

1

Rated output voltage (Vac)

230Vac

120Vac

Output voltage error

±5%

Output frequency range (Hz)

50Hz ± 0.3Hz

 

60Hz ± 0.3Hz

Maximum Efficiency

>92%

>91%

Overload protection

(102% < load <125%) ±10%: report error and turn off the output after 5 minutes;

(102% < load <110%) ±10%: report error and turn off the output after 5 minutes;

 

(125% < load < 150%) ± 10%: report error and turn off the output after 10 seconds;

(110% < load < 125%) ± 10%: report error and turn off the output after 10 seconds;

 

Load >150% ±10%: report error and turn off the output after 5 seconds;

(Load >125% ±10%): report error and turn off the output after 5 seconds;

Peak power

6000VA

8000VA

10000VA

4000VA

4500VA

5000VA

Loaded motor capability

2HP

3HP

4PH

1HP

2HP

2HP

 

 

 

 

 

 

 

Rated battery input voltage

48V (Minimum starting voltage 44V)

Battery voltage range

Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery... settable on LCD screen)

 

 

Power saving mode self-consumption

Load≤50W

AC charging

Battery type

Lead acid or lithium battery

Maximum charge current(can be set)

0-60A

0-40A

Charge current error

± 5Adc

Charge voltage range

40 –58Vdc

40 –60Vdc

Short circuit protection

Circuit breaker and blown fuse

Circuit breaker specifications

30A

40A

Overcharge protection

Alarm and turn off charging after 1 minute

PV charging

Maximum PV open circuit voltage

145Vdc

PV operating voltage range

60-145Vdc

MPPT voltage range

60-115Vdc

Battery voltage range

40-60Vdc

Maximum output power

3200W

4200W

PV charging current range (can be set)

0-60A

0-80A

Charging short circuit protection

Blown fuse

Wiring protection

Reverse polarity protection

Hybrid charging Max charger current specifications (AC charger+PV charger)

Max charger current(can be set)

0-120A

0-140A

0-120A

Certified specifications

Certification

CE(EN62109-1)

CE(EN62109-1)/ETL(UL 1741)

EMC certification level

EN61000, C2

Operating temperature range

-15°C to 55°C

Storage temperature range

-25°C ~ 60°C

Humidity range

5% to 95% (Conformal coating protection)

Noise

≤60dB

Heat dissipation

Forced air cooling, variable speed of fan

Communication interface

USB/RS485(WiFi/GPRS)/Dry node control

Size mm

378*280*103

426*322*124

(L*W*D)

 

 

Weight (kg)

6.2

10.8