Model | JHF-1101(L) | JHF-1102(L) | JHF-1103(L) | JHF-1106(L) | JHF-1110(L) |
| JHF-1101(L)-RM | JHF-1102(L)-RM | JHF-1103(L)-RM | JHF-1106(L)-RM | JHF-1110(L)-RM |
Capacity | 1KVA/1KW | 2KVA/2KW | 3KVA/3KW | 6KVA/6KW | 10KVA/10KW |
Host Machine Specification |
UPS Structure | Online Double Conversion |
Appearance | Tower or Rack mount structure design |
Overall Efficiency | > 95%(98.5% under ECO mode) |
Noise(In 2 meters) | < 50dB |
Working Temp | -10-40℃ |
Storage Temp | -15-60℃(without batteries) |
Humidity | < 20-95% Non-Condensing |
Maintenance bypass | / | optional |
protection | Overload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low |
Alarm | Mains abnormal or Fault, BAT Voltage High/low,over load、UPS fault, shot circuit etc |
Cabinet Standard | IP20 |
Cooling System | Intelligent Speed Control Cooling Fan |
Altitude | <11000M,Without Derated, 1000m <altitude< 1500m, refer to IEC62040 |
Rectifier Specification |
Input Voltage | 220Vac(208/220/230/240Vac available) |
Input Voltage Range | 100%load:180-300Vac,50% load:110-300Vac | 110~300Vac 110~176VAC/276~300VAC |
Input Frequency Range | 44~56Hz or 54Hz~66Hz |
Input PF | 0.99 |
THDI | ≤ 3% linear load,≤ 5% Non-linear load |
Output Specification |
Output Voltage | 220Vac(208/220/230/240Vac available) |
Output PF | 1.0 (0.9 default type) |
Output Voltage Regulation | 220Vac±1%(Static Load);220Vac±2%(50-0% Sudden Change);220Vac±5%(100-0% Sudden Change) |
Output Freq(Battery) | 50Hz±0.1%(Battery mode)60Hz can be customized |
Wave form | Pure sine wave |
Distortion | < 2%(Linear Full Load),< 4%(100% Non-Linear Full Load) |
Overload | 125% More than 1 Min; >150% bypass mode and UPS turn off |
Crest Ratio | 3∶1 |
Inverter efficiency | > 95% |
Short circuit | Circuit Auto Protection,Output Voltage/Current 0 |
Noise Suppression | EMI/RFI Wave Filter |
Battery voltage low | Shut down protection |
Dynamic Response | 3% at full load, recovering in 20ms |
Auto restart function | available |
Software set on/off | available |
Bypass Specification |
Static Bypass Transfer Time | 0ms(the Static breaker phase lock control technology) |
Static Bypass Range | 80Vac±5%~285Vac±5% |
Battery Specification |
Type | Sealed Lead Acid Maintenance Free |
Model Rated Volts/Units | 12V/7Ah*2nos | 12V/7Ah*4nos | 12V/7Ah*6nos | 12V/7Ah*16nos |
Std. Built-in BAT type backup time | 5-15mim | 5-15mim | 5-15mim | 5-15mim | 5-15mim |
Ext. Model rated voltage | 36Vdc | 72Vdc | 96Vdc | 192 Vdc defult /240Vdc (optional) |
Charging current | Std.Built-in model 1A、Ext. model 5-10A | Std. Built-in model 1A、Ext. model 6-12A |
Communication Specification |
Communication Port | Std.RS232/EPO;SNMP/485/dry contact(optional) |
Remote Software | Multi-functional Monitoring System, Online and BAT Mode Status, utility fault, BAT Fault, Remote Control |
Physical Parameters |
Size mm (W×D×H) | Std. type | 145×285×215 | 145×400×215 | 190×420×318 145×400×215 | 190×390×705 |
Ext. type | 190×360×335 |
RM/RT type | 440×400×88/2U | 440×450×88/2U |
Weight Kg | 9/5 | 15/7 | 20/8 | 57/12 | 67.5/12.5 |
5 | 7 | 8 | 12 | 12.5 |