WLF Three Phase Low Frequency Double-Conversion Online UPS |
Power Rating | 10KVA/ 8KW | 15KVA/ 12KW | 20KVA/ 16KW | 30KVA/ 24KW | 40KVA/ 32KW | 60KVA/ 48KW | 80KVA/64KW | 100KVA/ 80KW | 120KVA/ 96KW | 160KVA/ 128KW | 200KVA/ 160KW |
Mains Input |
Rated Voltage | 3 x 380VAC/400VAC/415VAC (3Phase + N) |
Voltage Range/Window | ± 25%VAC |
Frequency | 50/60 Hz ± 10 % |
Bypass Input |
Rated Voltage | 3 x 380VAC/400VAC/415VAC (3Phase + N) |
Voltage Range/Window | +10%, +15%, +20% (can be set); -10%, -20%, -30% (can be set) |
Frequency | ±2% (±0.5%, +1%, ±2%, ±3% can be set) |
Output |
Output Voltage | 3 x 380VAC/400VAC/415VAC (3phase + N) |
Voltage Accuracy | Static: ±1% Typical value Transient: ±5% Typical value( load change 100-0-100%) |
Frequency(Synchronization correction range) | 50/60 Hz synchronize ±1 % Mains Loss ±0.1 Hz |
Frequency Tracking Rate | ±1 Hz/s |
Output Waveform | Pure Sine Wave |
TotalHarmonic(THDv) | <2% (Linear Load) ; <5% (Nonlinear Load) |
Phase Unbalance | 120º ±1% (Balance Load) ; 120º ±2% (50% Unbalance Load) |
Time for adjustion (Dynamically) | 3 cycles returned to rated 90% |
Overload Capacity | 110%~ 150% 10minutes~1 minute;150%~ 160% >1 minute~200ms;200ms for>160% |
Peak Factor | 3:1 |
Load Power Factor Range | 0.6~1 (Capacitive or Inductive) |
Unbalanced output voltage @ 100% unbalanced load | <1% |
Current Limit | Very heavy overload, short circuit: voltage RMS limit; impulse current: peak voltage limit |
Efficiency | 91% | 91% | 92% | 93% |
Bypass |
Type | Static Switch |
Voltage | 3 x 380VAC/400VAC/415VAC (3Ph + N) |
Frequency | 50/60 Hz |
Control Way | Microprocessor Control |
Inverter to bypass switching time | Synchronous mode - switching uninterrupted, asynchronous mode - 10ms |
Overload Capacity | 150%~ 180% 1h~1s;180%~ 200%30s~200ms;200ms for>200% |
Switch to Bypass | Overload larger than 160% would be switched immediately |
Switch back to the inverter | The alarm is switched automatically after alarm clearing |
Maintenance Bypass |
Type | uninterrupted |
Voltage | 3 x 400V (3 Phase+ N) |
Frequency | 50/60 Hz |
Battery & Charging |
Battery Number(12V) | Standard is 32pcs; 29/30/32(Adjustable) |
Charging Mode | Option: constant voltage charging / constant current charging |
Charge Current | Default 10A, maximum 40A |
Battery Type and Quantity | Sealed lead-acid batteries, nickel cadmium battery |
Physical Performance |
Size,WxDxH(mm) | 300*600*810 | 400*750*1010 | 450*830*1160 | 700*800*1500 | 700*800*1700 |
Net Weight (KG ) (Without batteries) | 118 | 120 | 145 | 193 | 278 | 365 | 471 | 573 | 650 | 785 | 840 |