Welcome to Shenzhen SST Power.   |
+86-18718357506
daisy@sstpowerltd.com
Customized Isolation Transformers – Safeguarding Power Supply with Safety and Reliability
04/11 2025
With the rapid development of industrial automation and power electronics, the demand for safer and more stable electrical equipment continues to grow. To meet the diverse needs of various industries, Shenzhen SST Power introduces a new series of customized isolation transformers, offering flexible design options for capacity, voltage, and other key parameters to deliver efficient, secure, and reliable power solutions.Safe Isolation, Stable Power SupplyIsolation transformers play a critical role in power systems by effectively separating primary and secondary circuits, preventing electrical interference, reducing the risk of electric shock, and ensuring the safety of both equipment and personnel. Shenzhen SST Power’s isolation transformers are built with high-quality silicon steel cores and high-purity copper windings, featuring low power loss, high efficiency, and superior heat resistance. They are widely used in medical equipment, precision instruments, telecom base stations, and industrial control systems where high-quality power supply is essential.Flexible Customization for Diverse ApplicationsShenzhen SST Power provides fully customizable isolation transformers, including:Capacity Range: 1kVA to 2000kVA, supporting small-scale devices to high-power industrial applications.Input/Output Voltage: Available in single-phase or three-phase configurations, with customizable voltage levels (e.g., 128V, 220V, 380V, 480V, 600V).Special Features: Optional shielding layers, moisture-proof & corrosion-resistant coatings, and outdoor protection (IP65) for harsh environments.Quality Assurance, Global ServiceShenzhen SST Power operates advanced production lines and a strict quality control system, ensuring all products comply with ISO certifications and international safety standards for long-term reliability. Additionally, we offer professional technical support and responsive after-sales service to address any power-related challenges.Committed to customer-centric innovation, Shenzhen SST Power continues to provide energy-efficient, safe, and high-performance power solutions for global industries.About Shenzhen SST Power:Shenzhen SST Power is a high-tech enterprise specializing in the R&D and manufacturing of power equipment, including isolation transformers, voltage regulators, and power distribution systems. Serving industries such as industrial automation, healthcare, and renewable energy, we are recognized worldwide for cutting-edge technology and superior quality.
Diesel generator and Online UPS(Uninterruptible Power Supply) matching solution
11/04 2024
Generally, diesel generators distribute power to UPS systems, due to UPS interference such as harmonic feedback and sudden changes in load current, the ratio given by the design institute is 3:1, which means the capacity of the diesel generator needs to be 3 times the maximum load of the UPS.  But in fact, in GDS, CICC Data, and actual interconnected data centers, the optimal  ratio between diesel generators and UPS is 2 or 1.5:1, which not only reduces the cost but also improves energy utilization.When the UPS is used in conjunction with a generator, only a small amount of backup battery is needed for the UPS to prepare for switching.( Back-up time can be 5 to 15 minutes).  The conversion between the generator and the mains power can be done manually or with an automatic switching device (ATS). When the mains fails, the automatic switching device (ATS) will automatically switch to the generator, and the generator will automatically start after a certain time delay to provide power protection.In practical applications, different customers have different availability requirements for the power supply system, so the configuration methods of UPS and generators are also different. The following are the most common and economical options.As shown in the figure, the diesel generator is used as the backup power supply of the mains. When the mains power fails, since the generator takes a certain time to start and cannot provide instantaneous power, the UPS uses the battery to provide uninterrupted power supply. Shenzhen SST Power UPS is with ZERO Switch Time, it can play a very good role in protecting the user's load equipment. After the generator is running stably, the input of the UPS is switched from the mains to the generator to prevent the system power supply from being interrupted due to battery exhaustion. This solution can effectively solve the problem of instantaneous power outages and long-term power outages and ensure the continuity of equipment work. We have just shipped a 200KVA/160KW low frequency online UPS, equipped with a diesel generator, providing customers with a perfect solution and effectively protecting their load equipment.If you want to know more about UPS performance or supporting solutions, please contact our sales to learn more.
1KVA 2KVA 3KVA Single Phase Online UPS 100V 110V 120V 127V 115V Online Uninterruptible power supply with built in batteries
10/15 2024
1-6kVA Low-Voltage 110V 115V 120V 127V Online UPS SpecificationsFeatures:Zero switching timeDouble conversion pure online type, zero conversion time for battery mains power supply mode switching, support fixed frequency output, effectively ensure the reliability of load power supply.Adopt DSP digital control technologyAdopt advanced DSP digital control technology to provide stable and reliable sine wave power supply.Ultra-wide input voltage frequency range55-145Vac extremely wide input voltage and 40~70Hz frequency input range, compatible with harsh power environment, reduce battery discharge times and improve battery lifeExcellent load adaptability50Hz/60Hz power system self-adaptation, can support output 100/110/115/120/127V, 50/60Hz, widely adapt to various voltage and frequency standard equipment.Can be used with generatorWide input voltage and frequency range, can effectively isolate the bad power generated by the generator, and provide a pure, safe and stable power supply for the loadHigh input power factorUsing active power factor correction technology (PFC), the input power factor is above 0.99, effectively avoiding grid pollution and effectively reducing electricity billsReliable Product DesignAll glass fiber double-sided circuit material, with large span components, strong, corrosion-resistant, greatly improving environmental adaptability.Dust-proof designReasonable air duct design and three-proof paint coating can effectively avoid the accumulation of dust pollutants and corrode the circuit.Open designPowerful DSP core and open design architecture make the machine highly customizable, suitable for automation and intelligent monitoring system.ModelC1K-LVC1KS-LVC2K-LVC2KS-LVC3K-LVC3KS-LVC6K-LVC6KS-LVPower RatingVA/W1kVA/800W2kVA/1.6kW3kVA/2.4kW6kVA/5kWTypeDouble Conversion Online UPSInput & OutputSingle-phase input/Single-phase outputInputInputSingle-phase two-line (L,N)+ GroundInput VoltageL-N: 55~145VACFrequency40Hz-70HzPower Factor≥0.99OutputOutputSingle-phase two-line (L,N)+ GroundRated Voltage  110/115/120/127VACAccuracy±2%Frequency50/60±4Hz(Phase lock follows the mains)  /   50/60Hz±0.1%(Fixed frequency mode)Output WavePure sine waveOutput Distortion (THDV%)<2%(Linear load)<7%(Non-linear load)Overload Capacity1min@105%~125% rated load10s@125%~150% rated load0.5S@>150% rated load10min@105%~125%60s@125%~150%0.5S@>150%Efficiency Mains Mode88%89%90%92%Battery Mode85%86%87%90%BatteryandChargerBattery voltage/quantity①24VDC/2pcsInternal Battery36VDCExternalBattery48VDC/4pcsInternal Battery72VDCExternalBattery72VDC/6pcsInternal Battery96VDCExternalBattery144VDC/12pcsInternal Battery192VDCExternalBatteryBattery Capacity12V/7AHExternal battery decision12V/7AHExternal battery decision12V/7AHExternal battery decision12V/7AHExternal battery decisionBackup TimeHalf load ≥ 6 minutesHalf load ≥ 6 minutesHalf load ≥ 6 minutesHalf load ≥ 6 minutes  Charge CurrentStandard machine (battery built-in): 1ALong-term machine (external battery): 4AStructural ShapeCabinetTower/RackTower TypeC1KS: 145(W)X220(H)x250(L)mmC1K, C2KS: 145(W)X220(H)x318(L)mmC2K: 145(W)X220(H)x390(L)mmC3K/3KS: 190(W) x 318(H) x 368(L)mmC5KS-LV190(W)x360(H)x528(L)Rack size3KR/5KRS: 438mm(W) x 88mm(2U)(H) x 500mm(D)All other models L/S: 438mm(W) x 88mm(2U)(H) x 360mm(D)Weight Kg8.94.2145.921.68.33716Human Machine Interface LCD DisplayDisplay show input and output voltage, frequency, load percentage, working mode, machine statusCommunication InterfaceStandard RS232Expansion card slotOptional network monitoring card, support PC, mobile phone remote monitoring, MODBUS, dry contact card.Environment Temperature-10~45oCHumidity0-98% (No condensation)Noise<50dB @ 1 meters
Manufacturer of UPS power supply for medical equipment--Shenzhen SST Power
10/15 2024
Uninterruptible power supply systems are used to provide backup power during power outages or fluctuations to ensure that hospitals can continue to operate normally in the event of power failures or other electrical problems. Many critical equipment and systems in hospitals, such as operating rooms, ICUs, emergency rooms, laboratories, etc., have high requirements on the reliability of power supply, because power interruptions may have a serious impact on patient safety and medical services. A hospital UPS system usually consists of one or more UPS hosts, batteries and battery cabinet, and power input and output wires connected to the hospital power system. Medical systems, especially equipment such as CT machines and X-ray machines, must be equipped with UPS power supplies.How to choose the right medical ups power supply?1. An online UPS uninterruptible power supply with zero switching time needs to be selected.2. When supplying power to capacitive loads such as computers, its rated output power should be greater than 1.5 times the sum of the rated power of each computer equipment, and when supplying power to other electrical equipment, it should be 1.3 times the maximum calculated load.3. The inrush current of the load shall not exceed 150% of the rated current of the UPS.How to choose the UPS power supply for the hospital-related equipment? The following equipment options are suggested for your reference.1. Color ultrasound, biochemical analyzer, blood cell analyzer, plasma collector, electrolyte analyzer, chemiluminescence immunoassay analyzer, CT and nuclear magnetic resonance workstation and other equipment, basically 3000VA UPS uninterruptible power supply is enough for a single instrument, For some higher power models, 6000VA is enough.2. CT and nuclear magnetic resonance machines need industrial low frequency on-line uninterruptible power supplies with three-phase four-wire isolation transformers. The power is basically between 80KVA and 160KVA, of which 120KVA is used for CT machines, and 100KVA and 160KVA are used for nuclear magnetic resonance machines.3. According to statistics, medical equipment in general villages and towns in China is disturbed by power supply more than 40 times a month, mainly including voltage changes, power outages (including short-term power outages measured in milliseconds), phase loss, and poor phase balance. Among these interferences, a large part is easy to be ignored because the naked eye cannot detect and distinguish them, but it usually affects the normal and safe use of the equipment.Shenzhen SST Power Co., Ltd.'s medical dedicated UPS power supply is of high quality, reasonable price and first-class service. For medical equipment with different power ratings, there are special models for different requirements. If you want to know more about medical UPS power supply, you can directly log on to the company's website and consult their customer service.

WhatsApp
Skype
Wechat